| No. | Test Item | Unit | Test Value of YJWG-10 | |
| 1 | Tensile Strength | MPa | ≥16.0 | |
| 2 | Elongation at Break | % | ≥500 | |
| 3 | Test Temperature T Low Temperature Brittleness | ℃ Failure Count | -76 ≤15/30 | |
| 4 | Air Heat Aging (135±2℃、168h) Change Rate of Tensile Strength Change Rate of Elongation at Break |
% % |
≤±20 ≤±20 | |
| 5 | Hot Set Test:200℃、0.2MPa、15min Elongation under Load Permanent Deformation after Cooling | % % | ≤175 ≤15 | |
| 6 | Dielectric Dissipation Factor 50Hz,20℃ | – | ≤1.0×10-3 | |
| 7 | Relative Permittivity 50Hz,20℃ | – | ≤2.35 | |
| 8 | Volume Resistivity at 20℃ | Ω·m | ≥1.0×1014 | |
| 9 | Dielectric Strength | MV/m | ≥25 | |
| 10 | Carbon Black Content | % | Per customer requirement | |
| 11 | Note: Black A compound or natural A compound (corresponding to natural B compound or black B compound) can be supplied per customer requirement. | |||
Applicable to the insulation layer of overhead cables rated up to 10kV.
Please provide the following details to help our sales representatives better understand your needs and get In touch with you as soon as possible.
-反白-1024x290.png)
Connecting the World
Powering the Future
Products