HTLS Gap Conductor (GZTACSR/EST)

Gap-type Thermal-resistant Aluminum-alloy Conductor Extra-high-strength Steel Reinforced

Characteristics:
-Super thermal resistant aluminum alloy, double current carrying capacity at continuous working temperature 210℃.
-Extra high strength steel core, to support the whole tension of conductor and  stress on steel core only.
-Gap structure between aluminum layer and steel core. T shaped aluminum alloy wire to form the gap & tube structure. Gap filled with grease, steel core slip freely for the load transfer during stringing.
-High temperature low sag performance, upgrading the line capacity without replacing tower, saving space and land resources.
-Convenient installation.
Standards:
IEC 61089Round wire concentric lay overhead electrical stranded conductors
IEC 62219Overhead electrical conductors-Formed wire, concentric lay, stranded conductors
IEC 62420Concentric lay stranded overhead electrical conductors containing one or more gap(s)
EN IEC 62641Conductors for overhead lines – Aluminium and aluminium alloy wires for concentric lay stranded conductors
EN IEC 63248Conductors for overhead lines – Coated or cladded metallic wire for concentric lay stranded conductors
EN 50182Conductors for overhead lines – Round wire concentric lay stranded conductors
Other international standards according to customers’ requirements

Code NameCross Section of Al

(mm2)

Cross Section of Steel

(mm2)

Diameter of Structure 1

(mm)

Diameter of Structure 2

(mm)

Rated Tensile Strength

(kN)

Max. DC Resistance @20℃

(Ω/km)

Nominal Weight

(kg/km)

Current Capacity

(A)

GZTACSR-185/30197.6031.6719.718.781.10.14838011095
GZTACSR-260/40265.3043.1122.621.7109.30.110610841335
GZTACSR-370/40370.5040.0826.024.81210.079213481651
GZTACSR-450/50444.7149.4828.427.2147.40.066016441867
GZTACSR-500/60523.5063.5531.229.5183.30.056019512087
GZTACSR-630/50642.7052.8334.032.0186.00.045621952386
Other designs according to customers’ requirements

Note: Current capacity is based on ambient temperature 40℃, Wind velocity 0.5m/s, Wind direction: 0 Degree, Solar radiation 0.1w/cm2, Absorptivity of conductor surface 0.9.

Transmission of high current carrying capacity, suitable for line upgrading without replacing tower. High temperature low sag performance, increase current capacity by 100%, yet no need to replace tower.