
Silane Cross-linked Polyethylene Insulation Compound for Cables
| №. | Test Item | Единица | Test Value of YJWG-10 | |
| 1 | Устойчивость к растяжению | MPa | ≥16.0 | |
| 2 | Elongation at Break | % | ≥500 | |
| 3 | Test Temperature T Low Temperature Brittleness | ℃ Failure Count | -76 ≤15/30 | |
| 4 | Air Heat Aging (135±2℃、168h) Change Rate of Tensile Strength Change Rate of Elongation at Break |
% % |
≤±20 ≤±20 | |
| 5 | Hot Set Test:200℃、0.2MPa、15min Elongation under Load Permanent Deformation after Cooling | % % | ≤175 ≤15 | |
| 6 | Dielectric Dissipation Factor 50Hz,20℃ | – | ≤1.0×10-3 | |
| 7 | Relative Permittivity 50Hz,20℃ | – | ≤2.35 | |
| 8 | Volume Resistivity at 20℃ | Ω·m | ≥1.0×1014 | |
| 9 | Dielectric Strength | MV/m | ≥25 | |
| 10 | Carbon Black Content | % | Per customer requirement | |
| 11 | Note: Black A compound or natural A compound (corresponding to natural B compound or black B compound) can be supplied per customer requirement. | |||
Applicable to the insulation layer of overhead cables rated up to 10kV.
Пожалуйста, предоставьте следующие данные, чтобы помочь нашим торговым представителям лучше понять ваши потребности и связаться с вами как можно скорее.
-反白-1024x290.png)
Соединяя мир
Обеспечивая будущее
Продукты
Быстрая ссылка