{"id":3914,"date":"2026-04-11T08:52:06","date_gmt":"2026-04-11T08:52:06","guid":{"rendered":"https:\/\/www.zttgroup.com\/?post_type=product&#038;p=3914"},"modified":"2026-09-23T05:39:16","modified_gmt":"2026-09-23T05:39:16","slug":"cable-retardante-de-llama-y-resistencia-al-fuego","status":"publish","type":"product","link":"https:\/\/www.zttgroup.com\/es\/product\/flame-retardant-and-fire-resistance-cable\/","title":{"rendered":"Cable retardante de llama y resistencia al fuego"},"content":{"rendered":"<p>Descripci\u00f3n del Producto<\/p>\n<ul>\n<li>GYHTZSH58-FR \u2013\u00a0los cables se fabrican insertando fibras \u00f3pticas de modo \u00fanico en tubos sueltos hechos de material de poli\u00e9ster de alto m\u00f3dulo (PBT), con compuestos impermeables llenos dentro de los tubos. Se utilizan elementos de resistencia no met\u00e1licos en el centro del cable \u00f3ptico. Los tubos sueltos (y posibles cuerdas de relleno) se retuercen alrededor del elemento de resistencia central para formar un n\u00facleo de cable circular compacto. La cinta de acero corrugado se envuelve longitudinalmente. Despu\u00e9s, se extruye una capa de funda interna retardante de llama, libre de hal\u00f3genos y de bajo humo. Tambi\u00e9n se proporciona una capa de cinta de mica resistente al fuego en la superficie de la funda interna. Finalmente, la cinta de acero se envuelve longitudinalmente y luego se extruye una funda externa retardante de llama, libre de hal\u00f3genos y de bajo humo en un cable.<\/li>\n<li>GYFHTH-FR Los cables se fabrican insertando fibras \u00f3pticas de modo \u00fanico en tubos sueltos hechos de material de poli\u00e9ster de alto m\u00f3dulo (PBT) con compuestos impermeables llenos dentro de los tubos. Se utilizan elementos de resistencia no met\u00e1licos en el centro del cable \u00f3ptico. Los tubos sueltos (y posibles cuerdas de relleno) se retuercen alrededor del elemento de resistencia central para formar un n\u00facleo de cable circular compacto. Se proporciona una capa resistente al fuego fuera del n\u00facleo del cable y despu\u00e9s se extruye una capa de funda de poliolefina retardante de llama, libre de hal\u00f3genos y de bajo humo (LSZH) para formar el cable.<\/li>\n<li>GYMXTPH-FR el cable \u00f3ptico se construye insertando fibras \u00f3pticas de modo \u00fanico o multimodo en un tubo suelto de metal hecho de acero inoxidable 304, con compuestos impermeables llenos dentro de los tubos. Se extruye una funda de poliolefina retardante de llama, libre de hal\u00f3genos y de bajo humo (LSZH) para formar el cable. Se colocan dos alambres de acero paralelos a ambos lados de la funda externa.<\/li>\n<\/ul>\n<p>Ventajas del Producto<\/p>\n<ul>\n<li>Control razonable de la longitud excesiva de la fibra \u00f3ptica, resistiendo la rotura de la fibra \u00f3ptica causada por la expansi\u00f3n y contracci\u00f3n t\u00e9rmica del cable \u00f3ptico durante el proceso de prueba.<\/li>\n<li>GYFHTH-FR El cable \u00f3ptico consiste en materiales refractarios de alto rendimiento para proporcionar protecci\u00f3n de aislamiento t\u00e9rmico para las fibras \u00f3pticas, y utilizando altas temperaturas, se puede formar una capa efectiva a prueba de fuego.<\/li>\n<li>Materiales seleccionados resistentes al fuego y a altas temperaturas \u2013 cinta de mica, para proporcionar excelentes efectos a prueba de fuego y de aislamiento t\u00e9rmico.<\/li>\n<li>La funda externa est\u00e1 hecha de material altamente retardante de llama, y el cable \u00f3ptico tiene excelentes caracter\u00edsticas retardantes de llama.<\/li>\n<li>La estructura de doble funda y doble armadura asegura un excelente rendimiento mec\u00e1nico y ambiental del cable \u00f3ptico.<\/li>\n<li>Cumple con los m\u00e1s altos requisitos de la norma BS 6387 para la resistencia al fuego de clase CWZ, asegurando la integridad de las l\u00edneas de comunicaci\u00f3n.<\/li>\n<li>El tubo de acero inoxidable 304 tiene una excelente resistencia a da\u00f1os por animales.<\/li>\n<li>Puede aliviar efectivamente la tensi\u00f3n de los recursos de tuber\u00edas causada por la expansi\u00f3n de las redes de tuber\u00edas de comunicaci\u00f3n dentro de las ciudades.<\/li>\n<li>Puede ser construido y tendido en secciones, con r\u00e1pida velocidad de soplado de aire, larga distancia de tendido y alta eficiencia de construcci\u00f3n.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Los cables \u00f3pticos retardantes de llama y resistentes al fuego pueden controlar la propagaci\u00f3n del fuego durante un incendio y mantener la integridad de la l\u00ednea de comunicaci\u00f3n. Puede cumplir con los requisitos de normas retardantes de llama y resistentes al fuego como CPR, UL e IEC60332.<\/p>","protected":false},"featured_media":6761,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[120],"product_tag":[],"class_list":["post-3914","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-fiber-cable","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.4 (Yoast SEO v21.4) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Flame Retardant and Fire Resistance cable - ZTT<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.zttgroup.com\/es\/product\/cable-retardante-de-llama-y-resistencia-al-fuego\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Flame Retardant and Fire Resistance cable\" \/>\n<meta property=\"og:description\" content=\"Flame-retardant and fire-resistance optical cables can control the spread of fire during a fire and maintain the integrity of the communication line. It can meet the requirements of flame retardant and fire-resistant standards such as CPR, UL, and IEC60332.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.zttgroup.com\/es\/product\/cable-retardante-de-llama-y-resistencia-al-fuego\/\" \/>\n<meta property=\"og:site_name\" content=\"ZTT\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-23T05:39:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.zttgroup.com\/wp-content\/uploads\/2026\/04\/Flame-Retardant-And-Fire-Resistance-Cable.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/\",\"url\":\"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/\",\"name\":\"Flame Retardant and Fire Resistance cable - ZTT\",\"isPartOf\":{\"@id\":\"https:\/\/www.zttgroup.com\/#website\"},\"datePublished\":\"2026-04-11T08:52:06+00:00\",\"dateModified\":\"2026-09-23T05:39:16+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.zttgroup.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/www.zttgroup.com\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Flame Retardant and Fire Resistance cable\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.zttgroup.com\/#website\",\"url\":\"https:\/\/www.zttgroup.com\/\",\"name\":\"ZTT\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.zttgroup.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Cable retardante de llama y resistencia al fuego - ZTT","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.zttgroup.com\/es\/product\/cable-retardante-de-llama-y-resistencia-al-fuego\/","og_locale":"es_ES","og_type":"article","og_title":"Flame Retardant and Fire Resistance cable","og_description":"Flame-retardant and fire-resistance optical cables can control the spread of fire during a fire and maintain the integrity of the communication line. It can meet the requirements of flame retardant and fire-resistant standards such as CPR, UL, and IEC60332.","og_url":"https:\/\/www.zttgroup.com\/es\/product\/cable-retardante-de-llama-y-resistencia-al-fuego\/","og_site_name":"ZTT","article_modified_time":"2026-09-23T05:39:16+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/www.zttgroup.com\/wp-content\/uploads\/2026\/04\/Flame-Retardant-And-Fire-Resistance-Cable.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/","url":"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/","name":"Cable retardante de llama y resistencia al fuego - ZTT","isPartOf":{"@id":"https:\/\/www.zttgroup.com\/#website"},"datePublished":"2026-04-11T08:52:06+00:00","dateModified":"2026-09-23T05:39:16+00:00","breadcrumb":{"@id":"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.zttgroup.com\/product\/flame-retardant-and-fire-resistance-cable\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.zttgroup.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/www.zttgroup.com\/shop\/"},{"@type":"ListItem","position":3,"name":"Flame Retardant and Fire Resistance cable"}]},{"@type":"WebSite","@id":"https:\/\/www.zttgroup.com\/#website","url":"https:\/\/www.zttgroup.com\/","name":"ZTT","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.zttgroup.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es"}]}},"_links":{"self":[{"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/product\/3914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/comments?post=3914"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/media\/6761"}],"wp:attachment":[{"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/media?parent=3914"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/product_brand?post=3914"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/product_cat?post=3914"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zttgroup.com\/es\/wp-json\/wp\/v2\/product_tag?post=3914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}